1. Unboxing & Turntable Placement
Key Points
- Take all items out from package and check one by one: 1pc UT500RUWTPSYL150ProV6 heavy-duty rotating base, 1 power adapter, 1 infrared remote control, 1 USB A to B cable, 1 3.5mm shutter extension cord, 1 dedicated camera shutter cable, 1 paper user manual. Contact seller immediately if any accessory is missing;
- Placement rule: Put the turntable on flat hard table, stay away from soft cushion and vibrating machines; reserve at least 10cm space around the turntable to avoid collision of large objects during rotation;
- Load reminder: Standard turntable surface size is 50cm. If your item width exceeds 50cm, calculate the valid load via torque formula. Do not run full load for long service life.
2. Full Wiring Step-by-Step Guide

2.1 Power Connection
- Locate round DC power port on turntable side, insert small DC plug of power adapter tightly;
- Plug the AC plug of adapter into standard household wall socket;
- Toggle red power switch on turntable side, the device will self-check for 5 seconds and enter standby mode;
- Self-check signal: The turntable rotates slightly and stops, which means power supply works. If no movement, re-plug all cables and check socket power.
2.2 USB Cable Connection for PC
- Insert Type-B small head into turntable USB port, plug Type-A big head into spare PC USB port;
- Install CH340 serial driver first, driver package is available on official website. Installation steps: Open driver file → Click INSTALL → Pop-up “install success” means finish;
- After installation, you can see USB-SERIAL CH340(COMx) in Windows Device Manager (Ports section), note down COM number for later software connection;
- Note: Only one software can occupy the COM port at the same time. Close serial debugging tools before launching TurntableX.
2.3 Shutter Cable Wiring for DSLR
- Plug one end of shutter extension cord into 3.5mm audio jack on turntable;
- Connect the other end of extension cord with camera-specific shutter cable (Select E3/N3 for Canon, R1/S1 for Sony, R90 for Fujifilm, DC0/DC2 for Nikon);
- Insert camera dedicated plug tightly into camera shutter port;
- If you only shoot panoramic images with mobile phone, skip these wired cables and use Bluetooth ComXimShutter pairing directly.
3. Full Infrared Remote Operation
Key Points
- Precondition: Turntable powered on standby, point remote at infrared receiver window within 3 meters without shelter;
- Basic rotation control:
- Clockwise/Counter-clockwise button to change direction; Speed+/Speed- adjust rotation speed; Stop to halt immediately;
- Single angle buttons (0.1°/1°/5°/10°/15°…180°): Tap number key, turntable rotates designated angle once then stop for precise positioning;
- Four dedicated shooting modes:
- Continuous Rotation: Tap continuous key for non-stop uniform spin, ideal for live product display;
- Repeated Step Mode: Tap angle key first then repeat step key, rotate fixed angle → pause 4s → loop endlessly;
- Pendulum Swing Mode: Set angle first then swing key, turntable swings left and right around current central point;
- Multi-step One Circle Mode (Core for photography): Number keys 2/4/8/144 mean equal segments of 360°. Tap number, turntable pauses 2s and triggers shutter automatically, stop after full circle;
- Zero point function: Set Origin saves hardware zero; Return to Origin drives turntable via shortest path to eliminate angle drift for 3D scanning;
- Parameter Save: Tap Save after adjustment, parameters store in flash and keep after power off;
- Remote Limitation: Cannot edit pause time or real-time weight reading, precise configuration requires PC software.
4. Windows TurntableX Software Full Guide
4.1 USB Wired Connection Steps
- Finish USB wiring and CH340 driver installation, record COM number in Device Manager;
- Download TurntableX zip from official site, extract and run TurntableX.exe directly without installation;
- Select matching COM in top-left Link State box, baud rate keep 115200, click Connect;
- Successful connection sign: Log area continuously outputs ###, device panel displays model, unique EBC code and firmware version;
- Failure fix: Swap USB port, reboot turntable, close serial software, reinstall driver.
4.2 Wi-Fi Wireless Connection Steps
- Power on turntable, disconnect home Wi-Fi, search hotspot named UT500RUWTPSYL150ProV6;
- Fixed Wi-Fi password: 88889999, ignore “no internet” prompt and do not switch network;
- Turntable default IP: 192.168.181.181, port 8181, click Connect directly;
- Wireless mode suits long-distance photography studio layout.
4.3 Software Core Operation
- Custom rotation modes (More flexible than remote): Select Continuous / Intermittent / Swing on left panel, input angle, pause time, repeat times freely, tick Auto Shutter for auto capture;
- Independent shutter control: Separate Focus, Shutter, FocShutter buttons to trigger camera manually anytime;
- Weight detection: Calibrate scale in Load Measurement area, tap Set Offset under no-load for tare, real-time net weight display;
- Development debug area: Manually input CT commands in bottom TX box for testing, full command reference: Complete CT Command Parameter Table;
- Preset save: Tap Save after setup, load all shooting parameters with one click next time.
5. Mobile APP Operation
5.1 TurntablePlus for Wi-Fi Android
- Connect turntable hotspot in mobile WLAN, password 88889999;
- Install TurntablePlus APK, keep default IP and tap Connect;
- Visible panel to set rotation angle, interval, repeat times, tick auto shutter;
- Intuitive rotation & shutter buttons for on-site parameter adjustment without PC.
5.2 TurntableBLE Bluetooth Shooting
- Turn on Bluetooth & Location permission on Android (Mandatory for Android 12+);
- Search ComXimShutter in APP, pair without password;
- Turntable sends Bluetooth shutter signal automatically during pause, native mobile camera captures photos;
- Synchronous trigger for DSLR wired and mobile Bluetooth, dual material collection with single unit.
6. Full Auto 360 Product Shooting Workflow
Key Points
- Preparation: Place product at turntable center, fix camera on tripod, lock focus to avoid shifting;
- Cable match: Full shutter cable set for DSLR, only Bluetooth pairing for mobile shooting;
- Parameter example (32 photos per circle): Select 32-segment mode, 11.25° per step, 4s pause, enable auto shutter;
- Operation: Tap Start, auto capture at 2nd second of each pause, turntable stops after full 360°;
- Output usage: Export all-angle images for e-commerce 3D preview and panoramic product pages.
7. Beginner-Friendly Secondary Development Guide

7.1 Basic Introduction
- UT500RUWTPSYL150ProV6 programmable motorized turntable is standard SDK-controllable secondary development platform. USB, Wi-Fi, Bluetooth share identical plain-text CT commands with unified transmission format, no separated coding for different ports;
- Official open-source full Demo projects for Windows TurntableX & Android TurntableBLE, copy command logic to build custom control software and auto-test equipment;
- Fixed communication params: USB baud rate 115200; Wi-Fi TCP port 8181; General BLE TX/RX UUID;
- Command rule: All commands start with
CT+and end with semicolon;. Full definition, parameter range and feedback events refer to Complete CT Command Parameter Table.
7.2 High-Frequency Practical CT Commands
CT+TURNSINGLE(1,30);Rotate clockwise 30° and stop after single movement;CT+TURNSCLARK(0,1,4,36,4,20);Counter-clockwise repeated step, 36° per step, 4s pause, loop 20 times;CT+GOTOZERO();Turntable returns to hardware zero via shortest path;CT+GETWEIGHT();Read real-time load weight on platform;CT+SHUTTER();Manually trigger shutter signal once;CT+SAVEPARAM();Save all current rotation settings to turntable flash;
For full list of control, reading and event feedback commands, open Complete CT Command Parameter Table, which covers swing, full-circle shooting, firmware query, zero point event and all other interfaces.
7.3 5-Step Simple Debug Process for New Developers
- Step 1: Connect PC via USB, install CH340 driver, launch TurntableX and link turntable successfully;
- Step 2: Locate TX input box at software bottom, paste sample command and tap Send for test;
- Step 3: Observe turntable movement & RX feedback log to confirm normal execution;
- Step 4: Modify angle, pause time and loop value for repeated test, check Complete CT Command Parameter Table for complex functions;
- Step 5: Refer official Demo source code, transplant command transmission logic to self-developed Python/C#/Java programs.
8. Common New User Troubleshooting
Key Points
No feedback for development command: Check semicolon at command end, close serial occupied software, verify format on Comhttps://comxim.com/the-new-command-list/plete CT Command Parameter Table.ble and flexible solution for both professional users of e-commerce product shooting and 3D scanning, and developers who need to do automated control. If you have any questions during use, welcome to leave a message in the comment area.
Remote no response: Confirm turntable powered on, point receiver without shelter, replace remote battery;
Software fails to detect COM: Re-plug USB cable, swap PC USB port, reinstall CH340 driver;
Wi-Fi connection failure: Connect turntable exclusive hotspot only, password 88889999, do not switch home network;
Auto shutter not triggered: Re-seat shutter cables, tick Auto Shutter in software, confirm model with PS mark;
Leave a Reply