Practical Tutorial for MTxRUBSL Series Programmable Electric Turntable: Full Guide from Unboxing to Commercial-Grade 360° Shooting

As a technician with years of experience in product photography and automation equipment integration, I have handled dozens of electric turntables. The MTxRUBSL series stands out as one of the best options. It balances ease of use, scalability, and commercial stability. This tutorial breaks down the entire process from unboxing to commercial application. Even beginners can follow these steps to configure the device and start 360° product shooting quickly.
1. Unboxing and Accessory List Check
After receiving the package, check all accessories first. This step prevents missing parts from disrupting your later operations.
Core Accessory List
- Main body of programmable electric turntable ×1
- Power adapter ×1
- Infrared remote control ×1
- USB data cable ×1
- Shutter extension cable ×1
- Camera shutter cable ×1
- Product manual ×1
Place all accessories on a flat desktop after the check. You will use these items sequentially in the following steps.
2. Hardware Wiring and Basic Power-on Preparation
This step ensures normal equipment operation. Check the wiring sequence and interface correspondence carefully. Incorrect connections will prevent the equipment from working properly.
Step 1: Equipment Placement and Environment Preparation
- Place the turntable body on a horizontal, flat, hard surface. Do not place it on soft surfaces like beds or sofas. Soft surfaces cause shaking or slipping during operation.
- Reserve enough space around the equipment. This prevents the turntable from hitting surrounding objects during rotation. Also ensure that power and data cables remain free from squeezing or pulling.
Step 2: Power Wiring and Power-on
- Find the power interface on the turntable body side. Insert the DC plug of the power adapter firmly into this interface.
- Plug the other end of the power adapter into a compliant mains socket. Confirm that the power supply works normally.
- Turn on the main power switch on the turntable body side. The equipment will enter standby mode. Some models will show indicator lights to confirm power-on status.
Step 3: Control and Shooting Interface Wiring (Select as Needed)
- For computer control, insert one end of the USB data cable into the turntable’s USB Type-B interface. Plug the other end into your computer’s USB port. This completes the hardware connection for the control link.
- For automatic camera linkage, first insert the shutter cable end into your camera’s shutter interface. Connect the other end to the turntable’s shutter cable interface via the extension cable. Make sure all connections are tight to avoid poor contact during shooting.
3. Practical Operation of Basic Functions of Infrared Remote Control
The infrared remote control offers the most basic and convenient control method. It suits quick debugging and temporary display scenarios. You need no software installation and can start operation right after unboxing.

Description of Core Button Functions
- Power switch button: Controls turntable start and stop. Press it once to run the turntable in the current mode. Press again to stop rotation.
- Angle setting buttons: Include shortcuts for common angles like 1°, 5°, 10°, 15°, 30°, 45°, 60°, 90°, 180°, and 360°. Press the corresponding button to set a single rotation angle.
- Speed adjustment buttons: Adjust the turntable rotation speed. Different speeds suit different display and shooting needs.
- Mode switching button: Switches between five core modes: continuous rotation, single-step rotation, reciprocating swing, repeated stepping, and 360° segmented one circle.
- Shutter trigger button: Manually triggers the camera shutter for a single shot. Use this for focus and composition confirmation during debugging.
Basic Operation Process
- Confirm that the turntable powers on and stays in standby. Aim the remote at the infrared receiving window on the turntable body. Ensure no obstructions block the signal.
- Press the mode switching button to select your desired rotation mode. For 360° product shooting, choose the “360° segmented one circle” mode.
- Press the angle setting button to set each segment’s rotation angle. For example, set each segment to 10° if you need 36 images for a full 360° view.
- Press the power switch button. The turntable will start running according to your set parameters. It will complete segmented rotation and automatic shutter triggers.
4. Guide to Full-Function Control of Computer Host Software
For fine parameter adjustment, batch automatic shooting, and real-time status monitoring, use the computer host software. The host software supports the MTxRUBSL series and enables custom configuration of all functions.
Step 1: Software Installation and Driver Configuration
- Visit the official ComXim website to download the host software package and corresponding driver. Complete the software installation by following the setup wizard.
- When connecting the device for the first time, your computer will automatically recognize the serial port device. If recognition fails, manually install the CH340 serial port driver. This ensures the software can detect your device.
- Open the host software and select your turntable device from the connection list. Click connect, and the software interface will display real-time device status. You will see current angle, operation mode, rotation speed, and other information.
Step 2: Fine Parameter Configuration
- Mode customization: The host software supports detailed parameter adjustments for all five basic modes. You can set pause duration for reciprocating swing, interval time for repeated stepping, and shutter trigger timing for 360° segmented shooting.
- Fine adjustment of angle and speed: Input precise angle and rotation speed values. You can achieve angle control accurate to 1°. This meets the needs of high-precision 3D scanning and product modeling.
- Shutter parameter setting: Customize the shutter trigger advance amount and exposure time adaptation. This ensures compatibility with different DSLR camera brands and models. It prevents shutter triggers that fire too early or too late.
Step 3: Automatic Shooting Process Configuration
- Set the number of segments, angle per segment, pause duration, and shutter trigger switch for 360° segmented shooting in the host software.
- Click the “Start Shooting” button, and the turntable will automatically complete 360° rotation, pause at each segment point and trigger the camera shutter. No manual intervention is required during the whole process, and a complete set of 360° product materials can be shot at one time.
- After the shooting is completed, the software will automatically record the shooting log, and you can view the rotation angle corresponding to each photo, which is convenient for subsequent material sorting and image retouching.
5. Linkage Configuration for 360° Automatic Shooting
360° product shooting represents the core commercial scenario for the programmable turntable. This section breaks down the complete linkage configuration process clearly. Even novices can succeed on their first attempt.

Preparatory Work
- Complete the hardware wiring and power-on of the turntable. Connect your camera to the turntable via the shutter cable. Confirm that the camera powers on, stays in shooting mode, and has sufficient battery.
- Complete the product placement: Place the product in the center of the turntable surface. Ensure the product’s center of gravity remains stable. It should not tip over or shift during rotation.
- Complete focus and composition: Manually adjust camera position, focal length, aperture, and shutter speed. Lock the focus parameters after confirming the picture quality. This prevents focus shift during rotation.
Core Configuration Process
- Select the rotation mode: On the remote control or host software, choose “360° segmented one circle.” This mode is specifically designed for 360° product shooting.
- Set the number of segments: Choose the segment count based on your shooting needs. Conventional e-commerce product images typically use 36 segments (10° per segment). For high-precision 3D scanning, you can set 72 segments (5° per segment). More segments produce smoother final materials but generate larger files.
- Set the pause duration: Set the pause time after each segment rotation completes. We recommend 3-5 seconds for most scenarios. This ensures the camera completes focusing, exposure, and shooting actions.
- Turn on the automatic shutter: Enable this function on the remote control or host software. Confirm that the shutter trigger signal works normally.
- Start shooting: Press the start button. The turntable will begin rotating automatically. It will stop after completing a full 360° rotation. The whole process needs no manual operation. You will obtain a complete set of 360° product display materials.
6. Quick Start for Secondary Development
The MTxRUBSL series programmable electric turntable opens a complete communication protocol and control instructions. It supports secondary development for integration into automated production lines, 3D scanning equipment, and customized shooting systems. This enables personalized automatic control.

Basic Development Preparation
- Communication interface: This series supports USB and Bluetooth BLE4.0 communication. Choose the appropriate channel based on your development scenario. The control instructions for both channels are fully compatible, eliminating duplicate development work.
- Development materials: Contact product technical support for the complete control instruction list, sample source code (Windows/Android platform), and communication protocol documents. All materials are open source and commercially available. You can perform secondary development directly based on the sample code.
- Development environment: Conventional languages like C/C++, C#, Java, and Python all work. No additional dedicated development environment is required. This lowers the development threshold.
Example of Basic Control Instructions
- Single-step rotation instruction:
CT+TURNSINGLE(direction, angle, speed);, This command enables a single rotation with specified direction, angle, and speed. For example,CT+TURNSINGLE(1,11.25,20);means counterclockwise rotation of 11.25° at a speed of 20 seconds per revolution. - Repeated stepping instruction:
CT+START(direction, mode, angle, pause time, cycle times);, This enables cyclic stepping rotation. You can also configure shutter trigger timing within this command. - Device status reading instruction: Use this command to read current angle, operation status, and fault information. This enables real-time monitoring and abnormal early warning.
Development and Implementation Process
- Set up the development environment and configure the corresponding communication port. Ensure normal communication between the device and your development system.
- Debug basic functions like device connection, instruction sending, and status reading using the official sample source code.
- Write your own control logic based on business needs. Examples include automatic rotation shooting for 3D scanning, production line positioning, and multi-device linkage control.
- After completing function debugging, conduct a long-term stability test. Verify that the device’s accuracy and stability meet your requirements under prolonged operation.
7. Daily Maintenance and Troubleshooting of Common Problems
Proper daily maintenance effectively extends equipment service life and reduces failures. Quick problem troubleshooting prevents disruptions to your normal shooting and production work.
Key Points of Daily Maintenance
- Cleaning and maintenance: Regularly wipe the turntable surface and body with a dry soft cloth. Clean dust and debris from the surface to prevent particles from entering gaps. Do not use alcohol or corrosive liquids, as they damage the equipment shell and internal components.
- Storage environment: When not in use for extended periods, store the equipment in a dry, ventilated environment free from corrosive gases. Avoid humid, high-temperature, or low-temperature environments that damage internal components.
- Load specification: Use the equipment strictly within its rated load. Avoid prolonged overload operation. Overload accelerates wear on the internal motor and transmission structure, affecting accuracy and service life.
Common Problems and Troubleshooting Solutions
- Problem 1: The equipment cannot be started after power-on
- Troubleshooting solution: Check whether the power adapter is inserted tightly and whether the power socket has power; check whether the main power switch on the body is turned on; if it still cannot be started, replace the compatible power adapter and test again.
- Problem 2: The remote control cannot control the equipment
- Troubleshooting solution: Check whether the remote control battery has power; confirm that the remote control is aimed at the infrared receiving window of the turntable without obstruction; check whether the distance between the remote control and the equipment is within the effective range; if it still cannot be controlled, replace the remote control battery and test again.
- Problem 3: The computer host software cannot recognize the equipment
- Troubleshooting solution: Check whether the USB data cable is inserted tightly and whether it is the original compatible data cable; check whether the device driver is installed correctly, you can reinstall the CH340 serial port driver; replace the USB interface of the computer and test again to avoid recognition failure caused by interface failure.
- Problem 4: The shutter cannot be triggered during automatic shooting
- Troubleshooting solution: Check whether the shutter cable and shutter extension cable are inserted tightly, and whether they are compatible with your camera model; check whether the camera is in the shooting mode and has sufficient power; confirm that the automatic shutter function is turned on in the host software and the shutter parameters are set correctly; if it still cannot be triggered, replace the shutter cable of the corresponding model and test again.